HZ-384A Automatic Oxygen Bomb Calorimeter Calorific Value Testing Equipment

I.Summarize
HZ-384A Automatic Calorific Value Tester is used to measure the calorific value of solid, liquid and other combustible materials (coal, petroleum food, wood, biomass).
The instrument is a new type of energy-saving analysis instrument developed by our company. The calculation program carefully compiled improves the measurement accuracy greatly. Color and touch display,good user interface. The measurement process is automatically controlled to reduce human error. Print cartridge, dry base high position
II.Tech Data
Heat capacity: About 10500 J / K
Oxygen bomb capacity: 300ml
Oxygen charging pressure: 2.8 3.2 MPa
Pressure resistance: water pressure 20MPa
Temperature range: 0 40 degree
Response time: < 4="">
Resolution: 0.0001 degree
Linearity: < 0.08%="" per="" 5="" ℃="" temperature="" rise="">
Temperature measurement error: ± 0.003 degree for every 5 degree temperature rise range
Power: 30W
Ignition voltage: AC24 V
Ignition time: 5S
Common faults and troubleshooting
phenomenon | reason | handle |
1,Oxygen bomb leak | Aging or wear of rubber sealing ring | Replace the sealing ring |
2,Ignition failure | ① The circuit is blocked or the ignition wire is in poor contact ② The sample is wet ③ Poor contact between ignition wire or cotton thread and sample ④ The two electrodes are too dirty ⑤ Oxidation of ignition cap ⑥ The two electrodes are short circuited with the crucible (it is easy to burn the crucible and electrode at this time) | ① Check whether the wiring is well connected, whether the oxygen warhead is in good contact with the ignition cap, and whether the oxygen bomb is placed properly ② The sample is splashed with oxygen too fast ③ Re sample ④ Sand the electrode with sandpaper ⑤ Sand the ignition cap oxide with sandpaper ⑥ Replace the electrode or crucible and re load the sample |
3Incomplete combustion of sample | The sample is not flammable Insufficient oxygen or insufficient oxygen pressure | Wrap the sample with lens wiping paper, extend the oxygen filling time, and replace the oxygen cylinder |
4,After ignition, the temperature rises too high and the calorific value is too high | ① Agitator does not work ② Mixing blade falling off | ① The mixing shaft is stuck and the line is blocked ② Insert a cotton into the nylon rod connected with the mixing shaft and insert it again |
5,The test did not end for a long time | The ambient temperature is too high | Adjust the water temperature of the outer cylinder to the room temperature, or lower the indoor temperature |
6,Air leakage of oxygenator | Aging or wear of sealing ring of oxygenator | Replace the sealing ring |
Packing list
No. | Item | Qty |
1 | Main engine | 1 |
2 | Power cord | 1 |
3 | Oxygen bomb | 1 |
4 | Oxygen flushing instrument | 1 |
5 | Pressure gauge | 1 |
6 | Ignition wire | 3 |
7 | Cotton | 1 |
8 | Benzoic acid | 1 |
9 | Add drain pipe | 1 |
10 | Tweezers | 1 |
11 | Printing paper | 2 |
12 | Oxygen bomb support | 1 |
13 | crucible | 5 |
14 | Oxygen bomb sealing ring | 2 |
15 | Small scissors | 1 |
16 | 1mLSample injector | 1 |
17 | 5mLSample injector | 1 |
18 | 10mLSample injector | 1 |



Popularne Tagi: HZ-384A Automatic Oxygen Bomb Calorimeter Calorific Value Testing Equipment, China, suppliers, manufacturers, price, for sale, Calorific Value Testing Machine, Calorific Value Testing Equipment, oxygen bomb calorimeter, calorific value measuring instrument, coal calorific value meter, Calorific Value Tester, coal calormeter, bomb calorimeter laboratory HZ-384A, bomb calorimeter for coal testing, coal wood calorimeter, automatic digital bomb calorific meter